Punching Shear Calculator

Calculate punching shear capacity for flat slab-column connections per ACI 318.

Connection Parameters

Typical: ~225 sq ft tributary area x factored load

Punching Shear Check

FAIL

Utilization: 118.3%

Critical Section

Effective Depth (d)

6.75"

Perimeter (bo)

99.0"

Column Ratio (beta)

1.00

Critical Area

613 in²

Applied Stress (vu)

224.5

psi

Capacity (phi*vc)

189.7

psi

ACI 318 Checks

1. Basic: 4*sqrt(f'c)253.0 psi
2. Beta: (2+4/beta)*sqrt(f'c)379.5 psi
3. Perimeter: (2+alpha*d/bo)*sqrt(f'c)299.0 psi
Governing vc253.0 psi

Design Capacity

126.8 kips

Max with shear reinf: 190.2 kips

Options to increase capacity:

  • Increase slab thickness
  • Increase column size
  • Use higher strength concrete
  • Add drop panel or column capital
  • Use shear studs or stirrups

Punching Shear Design Notes

Critical Section

Located at d/2 from column face. For circular columns, use equivalent square with same area.

Alpha Values

  • Interior columns: alpha = 40
  • Edge columns: alpha = 30
  • Corner columns: alpha = 20