Noise Figure Calculator

Calculate cascaded noise figure using Friis formula and convert between noise figure and noise temperature.

Calculation Mode

Stage 1 (First in chain)

Stage 2

Stage 3

F_total = F1 + (F2-1)/G1 + (F3-1)/(G1 G2)

Total Cascaded Noise Figure

2.105 dB
Linear: 1.6237 | Te: 180.9 K

Stage Contributions

Stage 1NF: 2 dB, Gain: 20 dB
93.8%
Stage 2NF: 6 dB, Gain: 10 dB
4.8%
Stage 3NF: 10 dB, Gain: 15 dB
1.4%

First stage dominates noise performance - use low NF, high gain amplifier first

Noise Figure Reference

NF (dB)Te (K)Typical Use
0.535Satellite LNA
175Low noise preamp
2170Good RF amp
3290Standard amp
6865Mixer/IF amp
102610Passive mixer